¡á Àû ¿ë : ¾Ð·Â , dz¼Ó , dz·® , ¿Âµµ , ½Àµµ , rpm ´Ù±â´É ÃøÁ¤
¡áÃøÁ¤¹üÀ§
- ¾Ð·ÂÇÁ·Îºê
¾Ð ·Â : 0 to 1000 mmH2O, ºÐÇØ´É 1 mmH2O dz ¼Ó with Pitot tube or Debimo : 4 to 100 m/s, ºÐÇØ´É 0,1 m/s dz ·®with Pitot tube or Debimo : 0 to 65.000 m©ø/h, ºÐÇØ´É 0,1 m©ø/h
- ´ÜÀ§º¯È¯
mmH2O, mBar, KPa, InWg, mmHg, m/s, fpm, m©ø/h, cfm, l/s, m©ø/s
- º£ÀΠdz¼Ó ÇÁ·Îºê
dz ¼Ó : see probes section (below) dz ·® : 0 to 65.000 m©ø/h, ºÐÇØ´É 1 m©ø/h ¿Â µµ : -20 to +80¡ÆC, ºÐÇØ´É 0,1¡ÆC
- ¿¼± dz¼Ó ÇÁ·Îºê
dz ¼Ó : 0 to 30 m/s, ºÐÇØ´É 0,01 m/s <3 m/s, 0,1 m/s beyond dz ·® : 0 to 65.000 m©ø/h, ºÐÇØ´É 1 m©ø/h ¿Â µµ : -20 to +80¡ÆC, ºÐÇØ´É 0,1¡ÆC
- ¿Â/½Àµµ ÇÁ·Îºê
½À µµ : 3 to 98 %HR, ºÐÇØ´É 0,1% HR À̽½Á¡(³ëÁ¡) : -20 to +80¡ÆC, ºÐÇØ´É 0,1¡ÆC
- ¿Âµµ ÇÁ·Îºê
Pt100 (2 channels) : -100 to +400¡ÆC, ºÐÇØ´É0,1¡ÆC < 250¡ÆC, 1¡ÆC beyond Thermocouples K (2 channels) : -200 to +1300¡ÆC, ºÐÇØ´É 0,1¡ÆC < 999¡ÆC, 1¡ÆC beyond
- ŸÄÚ¹ÌÅÍ
ºñÁ¢Ã˽Ä(Optic) : 60 to 50.000 RPM, ºÐÇØ´É 1 RPM Á¢Ã˽Ä(Contact) : 30 to 20.000 RPM, ºÐÇØ´É1 tr/min and 4 to 2500 m/min, ºÐÇØ´É 0,1 m/min
¡á ¿ëµµº° ±â´É
- ¾Ð·Â°è :
Pressure, depressure, differential pressure, Integration of pressure (0 to 10), point/point averaging, automatic point/point averaging, automatic averaging Air flow with K Factor Air velocity and air flow with Pitot tube : point/point averaging, automatic point/point averaging, temperature compensation. Air velocity and air flow with Debimo : automatic averaging, temperature compensation
- ¿¼± dz¼Ó°è :
Air velocity, point/point averaging, automatic point/point averaging, automatic averaging, Air flow in duct and with cones. Pt100 temperature integrated in the probe
- º£ÀΠdz¼Ó°è :
Air velocity, Air flow and air flow with cone (¨ª100 mm vane), point/point averaging, automatic point/point averaging, automatic averaging Pt100 temperature integrated in the probe
- ¿Âµµ°è :
Pt100 temperature : 2 channels, delta T Thermocouple K temperature: 2 channels, delta T
- ¿Â/½Àµµ°è:
Relative and absolute humidity, Dew point Pt100 temperature integrated in the probe
¡á ±âº» ±â´É Autozero, Hold, MIN/MAX, printer output, manual or automatic data storage (recording of 8000 points), automatic luminance, automatic shut-down...
¡á SMART PRO PROBES
|
ÅëÇÕ SMART PRO ½Ã½ºÅÛ
Class 200, Class 300 ¸ðµ¨¿¡ Áö¿øµÇ´Â ´Ù¾çÇÑ Á¾·ùÀÇ ÇÁ·Îºê . ´Ù¿ëµµ ±³Ã¼ »ç¿ëÀÌ °¡´ÉÇϸç , ¿¬°á ½Ã ÇÁ·Îºê ÀÚµ¿ÀÎ½Ä ±â´É ¹× ±³Á¤ÀÏÀÚ Áö½Ã ±â´É . °¢°¢ÀÇ ÇÁ·Îºê´Â °³º° calibration certificate ¶Ç´Â adjusting certificate ¹ßÇà , ½á¸ÓÄ¿Çà K ¿Âµµ ÇÁ·Îºê´Â Á¦¿Ü
|
|
|
º£ÀΠdz¼Ó ÇÁ·Îºê
Vane ¨ª 70 mm dz ¼Ó : 0,3 to 35 m/s, ¿Â µµ : -20 to +80¡ÆC. ºÐÇØ´É : 0,1 m/s. Vane ¨ª 100 mm dz ¼Ó : 0,20 to 35 m/s, ¿Â µµ : -20 to +80¡ÆC. ºÐÇØ´É : 0,01 m/s from
0,2 to 3 m/s and 0,1 beyond. Telescopic vane ¨ª 16 mm dz ¼Ó : 0,6 to 40 m/s. Lenght 720 mm. ºÐÇØ´É : 0,1 m/s.
|
|
|
¿¼± dz¼Ó ÇÁ·Îºê
Hotwire probe ¨ª 8 mm, width 300 mm dz ¼Ó : 0,00 to 30 m/s, ¿Â µµ : -20 to +80¡ÆC. ºÐÇØ´É : 0,01 m/s 0 to
3 m/s and 0,1 beyond. Telescopic Hotwire probe ¨ª 10 mm, Length 900 mm
dz ¼Ó : 0,00 to 30 m/s, ¿Â µµ : -20 to +80¡ÆC. ºÐÇØ´É : 0,01 m/s to 0 to3 m/s and 0,1 beyond. |
| |
|
¿Â / ½Àµµ ÇÁ·Îºê
¨ª 13 mm, Length 110 mm. ½À µµ : 3 to 98%HR. ¿Â µµ : -20 to +80¡ÆC. ºÐÇØ´É : 0,1%HR |
|
|
ŸÄÚ¹ÌÅÍ
Optic tachometry probe ¨ª 17mm, Length 195 mm. rpm: 60 to 50000 rpm. ºÐÇØ´É : 1 rpm |
|
|
Á¢ÃË½Ä ¾î´ðÅÍ
Contact adapter for optical tachometry probe . rpm : 30 to 20000 rpm and 4 to 2500 m/min. ºÐÇØ´É : 0,1m/min. |
|
|
½á¸ÓÄ¿Çà K ¿Âµµ ÇÁ·Îºê
Wide range of Thermocouple K temperature probes : Ambiant, contact, penetration, general use... |
|
|
Pt100 ¿Âµµ ÇÁ·Îºê
Wide range of Pt100 temperature probes : Ambiant, contact, penetration | |
¡á ¾Ç¼¼¼¸®
|
ÇÁ¸°ÅÍ
Printer with rolls of paper, battery charger and 4 rechargeable batteries. Easy to use , you can print the value of the device screen at any time.
|
|
|
ÇÇÅ䯩ºê
Accuracy : more than 0,5 % for an alignment with to the fluid axis flow within 12¡Æ Pitot tubes conform to AFNOR.NF.X10.112.norm. Appendix 4 dated 14.9.77. Type : ellipsoidal head curved NPL Coefficient : 1,0015. Quality : Hard stainless steel; 4/4 to AFNOR / Z2.CND.17.12.
|
|
|
Debimo
DEBIMO ´Â »ç°¢ ¶Ç´Â ¿øÇü ´öÆ®¿¡ ¼Õ½±°Ô ¼³Ä¡ °¡´ÉÇϸç Àú·ÅÇÑ ºñ¿ëÀ¸·Î ¹Ý¿µ ±¸Àû Â÷¾Ð / dz¼Ó / dz·® ÃøÁ¤ . DEBIMO ´Â ¸ðµç KIMO Â÷¾Ð°è ( ¾Ð·Â Æ®·£½º¹ÌÅÍ , ÈÞ´ë¿ë ¾Ð·Â°è , ¸¶³ë¹ÌÅÍ , Â÷¾Ð½ºÀ§Ä¡ ) ¿Í ¿¬µ¿ °¡´ÉÇϸç , Á¤¹Ðµµ¸¦ ¿äÇϴ dz¼Ó / dz·® µð½ºÇ÷¹ÀÌ , ÄÁÆ®·Ñ ¹× ±â·Ï¿¡ ÀûÇÕ
dz ¼Ó : 3 to 100 m/s (9 Pa to 10000 Pa).
|
|
|
¿Âµµ ÇÁ·Îºê STKP type
|
|
|
ÇÁ·Îºê ¿¬Àå (Telescopic Extension)
Telescopic bent extension to 90¡Æ Length 1 m, compatible with all measurement probes.
|
|
|
¼ÒÇÁÆ®¿þ¾î
LPC Software with PC interface cable |
|
|
º»Ã¼º¸È£ÄÉÀ̽º
Protection cover made of Elastomere, with support and magnets. Only for Class 100.
|
|
|
¿¼± dz¼Ó ÇÁ·Îºê Extension
Straight extension ¨ª 10, length 300 mm for hotwire probe. Bent extension to 90¡Æ, ¨ª 10, length 250 x 50 mm for hotwire probes
|
|
|
Flow Cones
KIMO has designed and manufactures the flow cones as an essential instrument for measuring direct air flows in ventilators and HVAC systems . These instruments are for use with portable hot-wire anemometers of Class 100, 200 and 300 ranges. Different models are available dependant on the flows and diffuser sizes. |
|
|
Èæ ±¸ (Black Ball)
Developed and manufactured by KIMO, the Black Ball Thermometer is for measuring radiant temperature . Based on the black body principle, it consists of one sphere, which is equipped with a liquid expansion thermometer, Pt 100 or thermocouple temperature probe .
|
|
|
¾Ð·ÂÆ©ºê
Clear tube ¨ª 5 x 8 For permanent installation (m/l or 25m). Silicone tube ¨ª 4 x 7 Black or white, for test instruments (m/l or 25 m) |
|
|
Æ©ºê¿¬°á ¾Ç¼¼¼¸®
Straight connection for ¨ª 5 x 8 tube. T-connection for ¨ª 5 x 8 tube. Y-connection for ¨ª 5 x 8 tube. |
|